SUMMIT
STRUCTURAL PANELS
Behlen Industries puts the strength of one of North America’s largest steel building manufacturers directly into your hands.
With more than 45 years of experience, countless buildings across North America, and a growing portfolio of overseas projects, Behlen Industries are world-renowned for their quality and reliability. Through our sister company ARTSPAN Inc. we can offer insulated metal panels that are available in a variety of configurations, as seen below.
Summit panels are structural, self-framing panels that can reduce or eliminate the need for additional structural framework in your project. These panels can be used to form the floor, wall and roof systems of your building envelope.
- COVERAGE WIDTH: 36” (1067mm)
- PANEL LENGTHS: 4’ to 53’ (1219mm to 16154mm)
- EXTERIOR FACE: 24ga or 26ga galvanized G-90 (Z275) pre painted steel with light corrugation and wood-grain embossing
THICKNESS | 5” |
---|---|
EFFECTIVE R-VALUE* | 28.5 |
INTERIOR FACE 24ga deep corrugated galvanized G-90 (Z275) pre painted steel
* Thermal testing in accordance with ASTM C518.Standard Exterior Colours
White White
Stone Gray
Charcoal
Buckskin
Premium Exterior Colours
Dark Red
Heron Blue
Black
Frontier
Espresso
Standard Interior Colours
White White
Galvalume
Panel Orientation | Design Criteria | Allowable Loads (PSF) | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
4' | 5' | 6' | 7' | 8' | 9' | 10' | 11' | 12' | 13' | 14' | 15' | 16' | 17' | ||
Flat Side Up | Bending / Shear | 500 | 400 | 300 | 220 | 169 | 133 | 108 | 89 | 75 | 64 | 55 | 48 | 42 | 37 |
Deflection (L/180) | 400 | 225 | 149 | 110 | 90 | 85 | 80 | 73 | 65 | 58 | 50 | 42 | 23 | 13 | |
Flat Side Down | Bending / Shear | 500 | 400 | 333 | 253 | 193 | 153 | 124 | 102 | 86 | 73 | 63 | 55 | 48 | 43 |
Deflection (L/180) | 400 | 225 | 150 | 110 | 90 | 85 | 80 | 73 | 65 | 58 | 50 | 42 | 23 | 13 |
TABLE NOTES:
- Tables based on allowable stress design.
- Based on 5" Artspan panel with 24 ga light profile exterior and 24 ga fluted interior panel (Min Grade 50 ksi)
- Structural capacity of the purlins/girts are not considered and must be examined independently
- Fasteners are not considered and must be examined independently